Page 15 - Crestron Home CoolAtomation
P. 15

Configure Setpoint & Room Temperature






      On the BACnet Explorer Side


      Identify Setpoint Configuration Values
      Locate and click on CoolMasterNet from the Device list on the top right.

      Locate and click on CoolMasterNet from the Address Space list on the bottom right

      From CoolMasterNet’s sub-list, locate and click on XYZ set_temp/ room_temp,
      where XYZ represents the indoor unit being configured                                                          64  64

      Object Identifier in the BACnet Property list

      Notate the Type and Instance values



      On the Crestron Home Side

      Click on the Thermostat Setpoints menu

      Set the Mode to Single

      Input the Instance Number and Type discovered through your BACnet device                                                         6 5
      explorer for XYZ room_temp in the Temperature field
      Input the Instance Number and Type discovered through your BACnet device
      explorer for XYZ set_temp in the Heat Setpoint field